Practices by Discipline
PIP produces broadly applicable code-compliant practices.
Browse PIP Practices
Stainless Steel Globe Valve Descriptions
​This Practice provides detailed purchase descriptions for stainless steel globe valve tag numbers included in PIP Piping Material Specifications (PMSs) and used along with PIP PNSM0110 and the purchase order for the procurement of valves. This Practice also provides a cross reference for stainless steel globe valve tag numbers to applicable PIP PMSs.​
Technical Correction
Hot Service Insulation Materials and Installation Specification
​​This Practice provides requirements for materials and installation of hot service insulation systems on the external surfaces of piping and equipment, ambient to 649°C (1200°F). This Practice describes requirements for hot service insulation materials and accessories, storage and handling of materials, insulation application, extent of insulation, and documentation. ​
Technical Revision
Plain and Reinforced Concrete Specification (European Standards)
​This Practice provides requirements for furnishing and installing materials and for proportioning, mixing, placing, testing, and curing of cast-in-place plain and reinforced concrete. This Practice supplements CEN EN 206, Concrete - Specification, performance, production and conformity, CEN EN 13670, Execution of concrete structures, and all the other European Standards (EN) referenced in these documents. This Practice is based on European Standards. European Standards typically have national annexes to modify or define parameters for local conditions. Where a European Standard is referenced, it is always intended to be in conjunction with the relevant national annex unless noted otherwise in contract documents. ​​​​
New Practice
Installation of Flexible, Removable/Reusable Insulation Covers for Hot Insulation Service
​This Practice describes the minimum requirements for materials, fabrication, and installation of flexible, removable/reusable hot service insulation covers, ambient to 538°C (1000°F). This Practice does not address design requirements for passive fire protection. ​​​
Technical Revision
Nonshielded Power Cable Specification (Up to 2400 Volts)
​This Practice describes the minimum technical requirements for design, material, construction, inspection, testing, purchase, and shipping of single and multiple conductor solid dielectric, insulated, nonshielded copper cable rated up to 2400 volts. ​
Complete Revision
Shielded Power Cable Specification (5 kV to 46 kV)
​This Practice provides requirements for the purchase of single and multiple conductor shielded power cable rated at 5 kV to 46 kV. This Practice describes the minimum technical requirements for design, material, construction, inspection, testing, and shipping of solid dielectric, insulated shielded copper cable.​
Complete Revision
Stainless Steel Gate Valve Descriptions
​This Practice provides detailed purchase descriptions for stainless steel gate valve tag numbers included in PIP Piping Material Specifications (PMSs) and used along with PIP PNSM0110 and the purchase order for the procurement of valves. This Practice also provides a cross reference for stainless steel gate valve tag numbers to applicable PIP PMSs.​
Technical Correction
Grounding Installation Details
Complete Revision
General Instrument Accessory Details
​This Practice contains accessory details that can be added to a pressure or differential pressure transmitter installation detail. Included are seal pot, blowdown, fill tee, rod out, coplanar transmitters, and steam trace supply condensate return details. Instrument purge details are shown in PIP PCIGN200 - General Instrument Purge Details.​
Technical Revision
Plastic and Plastic-Lined Butterfly Valve Descriptions
​This Practice provides detailed purchase descriptions for plastic and plastic-lined butterfly valve tag numbers included in PIP Piping Material Specifications (PMSs) and used along with PIP PNSM0110 and the purchase order for the procurement of valves. This Practice also provides a cross reference for plastic and plastic-lined butterfly valve tag numbers to applicable PIP PMSs.​
Technical Revision
Low-Voltage Motor Control Centers
​This Practice describes the requirements for the design, fabrication, inspection, testing, and shipping of factory-assembled 600 V motor control centers. It includes requirements for buses, enclosures, motor starters, fused switches, and circuit breakers. All equipment described in this Practice is suitable for use in dry, nonclassified areas or in outdoor enclosures. Panelboards and adjustable speed drives are outside the scope of this Practice​.
Complete Revision
Application of Underground Coatings for Transmission Pipelines (Universally Applicable)
​This Practice provides minimum requirements for surface preparation and the application and inspection of shop-applied and field-applied protective coatings on pipe, field joints, and special fabrications intended for underground/buried service for transmission pipelines.​
New Practice