Mechanical
RFSB2000
Refractory Brick Installation Specification (Universally Applicable)
Abstract ↓
This Practice provides requirements for installation of refractory brick (firebrick) linings. Installation methods include preparation, laying, and repair of the firebrick linings. This Practice also describes requirements for firing firebrick linings, when required.
June 2024
Reaffirmation
Reaffirmation
Piping
PNCM0004
Valve Tag Number Designator System
Abstract ↓
This Practice describes the arrangement of PIP valve tag number designations for manually operated valves and requirements for each field within a designation. Designation requirements are provided for both PIP-developed and purchaser developed valve tag numbers.
June 2024
Technical Revision
Technical Revision
Process
PHSMV026
Hygienic Process for Food/Beverage/Consumer & CGMP Products Stainless Steel Ball Valve Descriptions
Abstract ↓
This Practice provides requirements for suppliers providing hygienic stainless steel ball valves included in PIP Piping Line Class Material Specifications. For the purposes of this practice, “Hygienic,” “Process,” or “Hygienic Process” refers to all Hygienic Processes for Food/Beverage/Consumer & Current Good Manufacturing Practices (CGMP) or other products requiring a clean design. Ball valves are most often used in utility systems, such as clean gas flow, steam, water, etc., that support hygienic processes; however, it is highly recommended to avoid use of ball valves in the hygienic process. If necessary, it is recommended that any product contact ball valves are designated as “Clean Out of Place (COP)” to prevent cross contamination between products and batches.
June 2024
Technical Revision
Technical Revision
Process
PHSMV025
Hygienic Process for Food/Beverage/Consumer & CGMP Products Stainless Steel Check Valve Descriptions
Abstract ↓
This Practice provides requirements for suppliers providing hygienic stainless steel check valves included in PIP Piping Line Class Material Specifications. For the purposes of this practice, “Hygienic,” “Process,” or “Hygienic Process” refers to all Hygienic Processes for Food/Beverage/Consumer & Current Good Manufacturing Practices (CGMP) or other products requiring a clean design.
June 2024
Technical Revision
Technical Revision
Piping
PNC00002
Abbreviated Piping Terms and Acronyms
Abstract ↓
This Practice provides a system for engineers to identify abbreviated piping terms and acronyms used in PIP piping Practices. This Practice establishes the definitions and interpretations for all piping-related abbreviations and acronyms used in piping Practices. Abbreviations for technical societies, codes, standards, etc., are not included.
June 2024
Technical Revision
Technical Revision
Piping
PLSC0018
Requirements for Welder Qualifications in Accordance with API 1104
Abstract ↓
This Practice provides minimum requirements for qualifying welders in accordance with API 1104. Welder qualification tests are given to determine the ability of the welder to make sound welds using qualified weld procedures (WPS). For welder qualification requirements in accordance with ASME Section IX, see PIP PLSC0017.
May 2024
Technical Revision
Technical Revision
Process
PHXP0PK0H01
Hygienic Process for Food/Beverage/Consumer & CGMP Products Material Specification XP0PK0H01 High Purity PVDF Pipe,C.A. – None, Butt Fusion Welded, SFP1ID Finish ≤ 10″, SFP2ID Finish ≥ 12″, PTFE Seals/Seats (Universally Applicable)
Abstract ↓
Not applicable
May 2024
Complete Revision
Complete Revision
Mechanical
VEFV1100
Vessel/Shell & Tube Heat Exchanger Standard Details (U.S. Customary Units) (Universally Applicable)
Abstract ↓
This Practice provides fabrication and installation details and dimensional tolerances for the design of supports and other attachments for vessels, heat exchangers and solids products containers.
May 2024
Complete Revision
Complete Revision
Mechanical
VEFV1100M
Vessel/Shell & Tube Heat Exchanger Standard Details (Metric Units) (Universally Applicable)
Abstract ↓
This Practice provides fabrication and installation details and dimensional tolerances for the design of supports and other attachments for vessels, heat exchangers and solids products containers. Dimensions are conversion of the PIP VESV1100 dimensions using the conversion guidelines of ASME Section VIII, Appendix GG.
May 2024
Complete Revision
Complete Revision
I/E
ELSSG04
Automatic Transfer Systems for Secondary Selective Substations
Abstract ↓
This Practice describes minimum requirements for design, performance, inspection, testing, and documentation of automatic delayed transfer systems (ATS) for two-source secondary selective substations, typically known as Main-Tie-Main transfer scheme. ATS provides automatic restoration of bus voltage upon loss of one of the sources. This Practice also covers remote monitoring and control requirements. This Practice does not cover fast bus transfer or delayed in-phase transfer systems.
May 2024
Complete Revision
Complete Revision
Process
PHCM0004
Hygienic Process Valve Tag Number Designator System (Universally Applicable)
Abstract ↓
This Practice provides the arrangement of PIP valve tag number designations for manually operated valves in hygienic service and requirements for each field within a designation. Designation requirements are provided for both PIP-developed and purchaser-developed valve tag numbers.
May 2024
Technical Revision
Technical Revision
I/E
ELSPF01
Medium-Voltage Metal-Enclosed Power Factor Correction Capacitor Specification from 2.4 kV to 35 kV
Abstract ↓
This Practice provides minimum requirements for design, fabrication, inspection, testing, shipment, and documentation, for metal-enclosed power factor correction capacitors, from 2.4 kV to 35 kV, containing lightning/surge arrestor, transient inrush or tuning reactors, vacuum circuit breaker, capacitor, capacitor protection, insulated buses, and control for indoor/outdoor installation in unclassified areas. This Practice covers fixed, manual, and automatic switched capacitor banks.
May 2024