Practices by Discipline
PIP produces broadly applicable code-compliant practices.
Browse PIP Practices
Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear
This Practice describes the requirements for metal-enclosed power switchgear assemblies employed in three-phase AC electrical systems having a voltage not greater than 1000 volts and located in a nonclassified area.
Complete Revision
Grounding Installation Details
The purpose of this Practice is to provide the typical details for construction of grounding systems in chemical and refining facilities. The bonding and grounding design and installation shall be in accordance with the National Electrical Code.These installation details include power system and equipment grounding, static grounding protection for equipment in classified locations, grounding electrode connections, and step and touch potential grounding.Not included in the scope of this Practice are computer and control system grounding and cathodic protection.
Complete Revision
Low-Voltage Motor Control Centers
This Practice describes the requirements for the design, fabrication, inspection, testing, and shipping of factory-assembled 600 V motor control centers. It includes requirements for buses, enclosures, motor starters, fused switches, and circuit breakers. All equipment described in this Practice is suitable for use in dry, non-classified areas or in outdoor enclosures. Panelboards and adjustable speed drives are outside the scope of this Practice.
Complete Revision
Standard Steel Doors and Frames Supplier Specification
This Practice provides supplier with requirements for all material, fabrication, finishes, and delivery of standard steel doors and frames.This Practice applies recommendations of the Steel Door Institute (SDI) of Westlake, Ohio.Comment It is recommended that SDI-108 be used to prepare contract documents.
Complete Revision
Standard Steel Doors, Frames and Related Hardware Installation Specification
This Practice provides constructor with requirements for installing standard steel doors, frames and related hardware. It applies recommendations of the Steel Door Institute (SDI) of Westlake, Ohio and the Door and Hardware Institute (DHI) of Chantilly, Virginia. This Practice does not include requirements for field-applied finish painting.
Complete Revision
Standard Steel Door Hardware Supplier Specification
This Practice provides supplier with requirements for all material, fabrication, finishes, and delivery of standard steel door hardware. This Practice is written without reference to specific manufacturers, brand names, or model numbers. Industry standards from American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) are used to specify performance and quality requirements for pieces of hardware.Hardware for aluminum entrance doors or specialty doors is not included.
Complete Revision
Medium-Voltage Motor Control Center Specification
This Practice describes the requirements for the design, materials, fabrication, inspection, testing, documentation, and shipment of metal-enclosed, NEMA Class E2 controllers (2001V to 7200V). This equipment is used for the supply, control, and protection of medium-voltage motors.
Complete Revision
Overall Electrical One-Line Diagram Guideline
This Practice is a guideline for developing Overall Electrical One-Line Diagrams (OEOLDs) by engineers and designers. It covers the generation of new OEOLDs and may not apply to the revision of existing OEOLDs.This Practice applies to one-line diagrams that fit the definition of an OEOLD in Section 3. This Practice uses ANSI/IEEE 315 - IEEE Graphic Symbols for Electrical and Electronics Diagrams and IEEE C57.12.80 - IEEE Standard Terminology for Power and Distribution Transformer symbols.The main purpose of an OEOLD is to provide an initial view of the electrical system for use in early design discussions. Then, the OEOLD can be updated as the project develops and kept current to provide a reference document that shows a high level view of the overall electrical system. As a secondary purpose and function the symbols provided for use in a OEOLD are intended to provide basic information. The basic information is shown in visible fields by default. Many OEOLD symbols have hidden or invisible fields that provide extra information or details. The invisible or hiddens fields can be changed to be visible based on owner requirements. This Practice can be applied to CAD systems used for developing OEOLDs, and is not supplier, hardware, or software specific. Electronic native files for the text, symbols, and cover sheets are available from PIP for use in CAD systems and have been developed in AutoCAD 2015. While the symbols can also be developed in Microstation DGN files, the functionality from AutoCAD may not be available in Microstation. Development of project-specific legend sheets is recommended using the PIP native files as a starting point. Additions and/or deletions are permitted to meet project requirements. Drawing borders and title blocks can be altered to be project specific.The guidelines in this Practice provide a balance between showing all data on OEOLDs and making OEOLDs legible and easy to read. Although this Practice describes major components in the electrical system, specific applications may require additional or alternative components. Determinations concerning fitness for purpose and matters of application of the Practice to a particular project or engineering situation should not be made solely on the information contained in this Practice.The OEOLD symbols included in the Appendices of this Practice are not intended to recommend specific design details or requirements. An example OEOLD is included to provide an illustration of how the elements of this Practice are combined into an OEOLD.
New Practice
Packaged, Skid-Mounted Industrial Process Refrigeration Systems Specification
This Practice describes the minimum requirements for the performance, design, fabrication, testing, inspection, and preparation for shipment of packaged, skid-mounted industrial process refrigeration systems. This Practice is not intended to cover commercial or absorption chiller systems.
Complete Revision
Process Flow Diagram Documentation Guidelines
This Practice provides general guidelines for the format and content of Process Flow Diagrams (PFDs) for process and utility systems.This Practice covers the development of new PFDs and does not apply to existing PFDs developed before the adoption of this Practice.The Practice applies to all diagrams that fit the definition of a PFD in Section 3.This Practice can be applied to any CAD system used for developing PFDs and is not vendor, hardware, or software specific.Although this Practice provides general guidelines for the development of PFDs, individual applications may require differing approaches than those recommended in this Practice. Determinations concerning fitness for purpose and matters of application of the Practice to a particular project or engineering situation should not be made solely on the information contained in this Practice.Example PFDs in the Appendixes of this Practice are not intended to recommend specific design details or requirements, but are included to provide illustrations of various options available to the user.
New Practice
Guidelines for Application of Remotely Actuated On-Off Valves
This Practice describes guidelines and background information for the application of remotely activated on-off valves. This Practice includes process application, valve and actuator selection, material selection, ancillary equipment requirements, and testing of remotely activated on-off valves (e.g., 2-way, 3-way, 4-way, etc.).This Practice covers non-throttling applications. Throttling applications are considered to be control valves and are covered in PIP PCECV001 and PIP PCCCV001. However, remotely activated on-off valves have many similarities with control valves (e.g., body configuration, materials of construction, internals, etc.). Therefore, this Practice should be used in conjunction with PIP PCECV001.
Technical Revision
Application of Internal Linings
This Practice provides requirements for installing industrial linings. This Practice describes the general requirements for surface preparation, environmental control, and the installation and inspection of liquid-applied internal linings to metal substrates. This Practice does not cover sheet linings and application of linings to piping.
Complete Revision
Insulation Inspection Checklist
This Practice provides a checklist for use by individuals responsible for ensuring the quality and completeness of an insulation job. This Practice describes the requirements for inspecting insulation by providing an Insulation Inspection Checklist, PIP INTG1000-F. The checklist is designed to apply to both cold and hot insulation systems as well as large-scale projects and individual items. As a result, there are specific items on the checklist that may not apply to all projects.Each section has a line for ranking workmanship. Because workmanship is somewhat subjective, ranking is provided.Comment sections are provided where appropriate.This Practice assumes that individuals charged with making the inspections are experienced in the design and installation of insulation systems and are well-acquainted with the PIP Insulation Practices.The checklist does not provide sufficient information to act as a stand-alone document that would allow an inexperienced person to function as an inspector.
Reaffirmation
Cold Service Insulation Materials and Installation Specification
This Practice provides requirements for materials and installation of cold service insulation systems. This Practice describes requirements for cold service insulation materials and accessories, storage and handling of materials, insulation application, extent of insulation, and documentation on the external surfaces of piping and equipment, ambient to -179°C (‑290°F).
Complete Revision
Design and Fabrication of Medium-Voltage Metal-Clad Switchgear Above 1000 V to 38 kV
This Practice covers minimum requirements for design, fabrication, inspection, testing, shipment, and documentation, for metal-clad switchgear containing insulated buses, draw-out power circuit breakers, control, instrumentation, and metering, for installation in unclassified areas. This Practice also covers remote monitoring and control requirements.
Complete Revision
Lighting and Receptacle Installation Details for Class I, Division 2, Class II, Division 2, and Unclassified Areas
This Practice provides installation details for luminaires and receptacles located in Class I, Division 2 areas, Class II, Division 2 areas, and unclassified areas. This Practice describes the basic assumptions used in developing these details and provides guidelines for their use.Installation details for Class I, Division 1 and Class II Division 1 areas are excluded from the scope of this Practice.
New Practice
Constructability Design Guide
This Practice provides engineers and designers with guidelines for improving the constructability of a project.This Practice describes guidelines for improving constructability of civil, structural, and architectural components of a project. This Practice provides guidelines for grass root projects, revamp projects, and turnarounds.
Complete Revision
Topographic and Plant Surveys Specification
This Practice in conjunction with PIP CVS02005-F - Survey Checklist describes the requirements for quality control, permits, deliverables, and execution for topographic and plant surveys. In case of conflict, the Survey Checklist supersedes this Practice.
Complete Revision